Home Cables Moduler Switch Appliances Accessories Contact Us
 :: UNIFY Cables ::        
  Cables Range Features Technical Data
             
 
Cables having circular bunched UNIFY copper conductors & high temperature PVC insulation. Rajdhani UNIFY conductors have no loose strands, ensuring that there is no loss of current carrying capacity due to breakage of strands during stripping of insulation and installation of cables. Compact high temperature PVC insulation gives short term rating of 125° C and continuous rating of 105° C. Thus the cables have high current carrying capacity.
 
  1. The Perfectly circulator conductor thus foamed is intergril and compact.
  2. This enables reduction in overall diameter for space saving in high density wiring.
  3. The strands don't get cut while stripping the insulation, thus conductor offers perfect contact at pins,
      terminals and sockets.
  4. This eliminates spot heating & sparking.
  5. Note that, many electricity meters run even when all switches are off, because of loose strands. Due
      to solidness of Rajdhani UNIFY cables losses does not happen. It reduces the consumption of
      electricity and electricity bills.
 
Manufactured from bright annealed 99.97% pure bare copper conductors with Rajdhani UNIFY bunched that offer low conductor resistance, they result in lower heating thereby increase in life and savings in power consumption. These wires are insulated with a special coloration which offers high insulation resistance and long life.
 
   
 
These Cables are used for wiring domestic and commercial buildings. The multi strand flexible conductors make it ideal for concealed wiring.
  Sizes, Deensions and Rating :   TRADITIONAL BUNCH CONDUCTOR
 
Conductor
Area
Sq. mm.
Insulation
Thickness
mm.
Configuration Max
Overall
Diameter mm.
Conductor Resistance Ohm/km @20*C
(Max)
Current Ratting Amps.
Casing Concealed
0.75 0.6 07/0.38 2.8 026 009 08
1.00 0.6 19/0.26 3.2 18.1 014 13
1.50 0.7 19/0.32 3.4 12.1 178 16
2.50 0.8 036/0.3 4.2 7.41 024 20
4.00 0.8 37/0.37 4.8 4.61 032 26
 
      UNIFY CONDUCTOR
 
 
Power wiring to appliances, wiring to terminals ,sockets and contact pins, wiring in areas closed to LPG such as kitchens, chemical factories, laboratories, industrial wiring, wiring susceptible to temorary overloads and all fixedf installation andoor wiring.
 
 
Properties Test Method Value
Limited Oxygen Index ASTM-2863 32%
Flame Propagation SS424-1475 Unburnt portion600/850 mm
Temperature Index ASTM-D 2863 250*C
 
      UNIFY CONDUCTOR
 
 
Powered by ViShEsh